Input Interfaces

  • ASI/SDI (Optional)
  • IP (Multicast or Unicast)

Transport Protocols

  • TS over ASI
  • TS over UDP (Multicast or Unicast)
  • TS over RTP/UDP (Multicast or Unicast)
  • TS over TCP
  • TS over Namepipe

Video Compression Formats

  • MPEG-1 Video (ISO/IEC 11172-2)
  • MPEG-2 Video (ISO/IEC 13818-2)
      Supported Profiles (All Levels):
    • Simple
    • Main
    • 4:2:2

    Note: HD is supported by Main Profile @ High Level.

  • MPEG-4 Part 2 Video (ISO/IEC 14496-2)
      Supported Profiles:
    • Short Video Header - Simple (L0  L5)
    • Advanced Simple (L0  L5)
      Supported Object Type:
    • Rectangular
  • H.264/AVC Video (ITU-T H.264)
      Supported Profiles (All Levels)
    • Baseline
    • Main
    • Extended
    • High
  • SMPTE VC-1 Video (SMPTE 412M)
      Supported Profiles (All Levels)
    • Simple
    • Main
    • Advanced

Audio Compression Formats

  • MPEG-1 Audio (ISO/IEC 11172-3)
  • MPEG-2 Audio (ISO/IEC 13818-3)
  • MPEG-2 AAC (ISO/IEC 13818-7)
  • MPEG-4 AAC (ISO/IEC 14496-3)
  • MPEG-4 HE-AAC (ISO/IEC 14496-3/Amd.1)
  • AC-3 (ATSC A/52B)
  • SMPTE 302M (SMPTE 302M)

Note: Multi-channel audio is down-mixed to stereo audio for output and level analysis

Closed Caption and XDS

    TeleSight supports real-time decoding of Closed Caption carried by:
  • EIA-608B over SCTE-20
  • EIA-608B over ATSC A/53
    TeleSight also supports real-time decoding of the following XDS data:
  • Program Name (Title)
  • Content Advisory (V-Chip), including MPA, U.S. PG, Canadian English, Canadian French
  • Copy Generation Management System, Analog (CGMS-A)

Transport Layer Analysis

  • Dropped packet detection for RTP layer
  • ESTI TR 101 290 tests for Transport Stream layer
      First Priority
    • TS sync loss
    • Sync byte error
    • PAT error
    • Continuity count error
    • PMT error
    • PID error
      Second Priority
    • Transport error
    • CRC error
    • PCR repetition error
    • PCR discontinuity indicator error
    • PCR accuracy error
    • PTS error
    • CAT error
      Third Priority
    • NIT actual error
    • NIT other error
    • Unreferenced PID
    • SDT actual error
    • SDT other error
    • EIT actual error
    • EIT other error
    • EIT PF error
    • RST error
    • TDT error

On Screen Error Display

    TeleSight displays the following critical errors over the video windows when they are detected:
  • No license
  • Disabled
  • No Signal
  • Scrambled
  • Black Video
  • Frozen Video

Video Layer Analysis

  • Video Stream Information
  • Video Picture Graph and Bitrate Profile
  • Video Quant Graph (Video Quality)
  • Video Conformance tests (From sequence level down to block level)
    • MPEG-2/MPEG-1 video conformance test. This test checks semantic rules and data integrity according to ISO/IEC 13818-2 (ISO/IEC 11172-2 for MPEG-1)
    • MPEG-4 v2 video conformance test. This test checks semantic rules and data integrity according to ISO/IEC 14496-2 (v2)
    • H.264/AVC video conformance test. This test checks semantic rules and data integrity according to ITU-T H.264
    • SMPTE VC-1 conformance test. This test checks semantic rules and data integrity according to SMPTE 421M
  • Black Video Detection with user configurable delay
  • Frozen Video Detection with user configurable delay

Audio Layer Analysis

  • Audio Stream Information
    • Audio Type
    • Audio Bitrate
    • Sampling Frequency
    • Channel Mode
    • Other compression format dependent information
  • Audio Wave Monitor
    • Short term wave window: 1 audio frame
    • Long term wave window: 5 second
    • Fast PPM with digital clipping indicator
  • PPM parameters
    • 0ms attack
    • 12dB/sec decay (fall back)
    • 4 sec hold for peak
  • Audio Level Test
    • Silence Detection
    • Max Level Detection
    • Digital Clipping Detection

Analysis/Test Report and History

  • Test summary of each source at system, video and audio level
  • Detailed test message of each error/warning type
  • Monthly, Daily and Hourly test history (error/warning count) over the past 12 months

Stream Capture

    TeleSight supports two different stream capture modes:
  • Automatic stream capture on error
    Users can enable capture on error for system, video and audio layer tests, and specify the maximum auto capture size of a source.
  • Manual stream capture
    Users can manually start and stop stream capture on a selected source.
  • Note: Input data before de-multiplexing are captured in both capture modes, except that RTP header can be dropped in manual mode.

Data Traffic Monitoring

  • IP layer traffic status
  • TS layer traffic status
  • Audio/Video layer traffic status
  • NTSC CC traffic status

Custom Layout and Labeling

TeleSight supports custom video layout and labeling. Video window can have different window sizes. Each output video can be positioned into any of the custom size window as long as there is no overlap. The video window label is also customizable. Users can select to display the service name decoded from the TS SDT tables, or the program title decoded from XDS data, or a custom name as the label of a video window. Different label color can be selected for different input sources.

Video Display Aspect Ratio and Alignment

TeleSight automatically adjust the video display aspect ratio according to the pixel aspect ratio of the video stream and the video display window size. Users can also select to align the video to the left side of a video window, or center it.

Analog and Digital Clocks

TeleSight supports both analog and digital on screen clocks. These clocks are fully resizable according to the window size they reside in, and they can be enabled or disabled separately.

Note: These clocks can be synchronized to a NTP server for better accuracy.

Dual Monitor Support

    TeleSight supports using two monitors to improve productivity. There are two modes:
  • Stretch mode
    In stretch mode, the video window can be displayed over the primary monitor and the control interface can be displayed over the secondary monitor.
  • Clone mode
    In clone mode, both monitors display the same content, the control interface can be hidden when it is not in used.